---
attributes: ~
cited_by: []
contributors: []
create_dt: 2012-10-28T12:59:00
description: ~
display_name: 76b0a8ed-2baa-4d9c-88f4-cc87d7bcea77
figures:
- attributes: ~
caption: 'Technology choices can significantly affect water and land use. These two panels show a selection of technologies. Ranges in water withdrawal/consumption reflect minimum and maximum amounts of water used for selected technologies. Carbon dioxide capture and storage (CCS) is not included in the figures, but is discussed in the text. The top panel shows water withdrawals for various electricity production methods. Some methods, like most conventional nuclear power plants that use âonce-throughâ cooling systems, require large water withdrawals but return most of that water to the source (usually rivers and streams). For nuclear plants, utilizing cooling ponds can dramatically reduce water withdrawal from streams and rivers, but increases the total amount of water consumed. Beyond large withdrawals, once-through cooling systems also affect the environment by trapping aquatic life in intake structures and by increasing the temperature of streams.78127ba4-136a-41c5-b02d-55a1b50f36ce Alternatively, once-through systems tend to operate at slightly better efficiencies than plants using other cooling systems. The bottom panel shows water consumption for various electricity production methods. Coal-powered plants using recirculating water systems have relatively low requirements for water withdrawals, but consume much more of that water, as it is turned into steam. Water consumption is much smaller for various dry-cooled electricity generation technologies, including for coal, which is not shown. Although small in relation to cooling water needs, water consumption also occurs throughout the fuel and power cycle.dd69310e-a111-413f-945e-85fde42c1cb9 (Figure source: Averyt et al. 20116c050821-4d0f-452a-9fb3-6576a5cc1c2e).'
chapter_identifier: water-energy-land-use
create_dt: 2012-10-28T12:59:00
identifier: water-use-for-electricity-generation-by-fuel-and-cooling-technology
lat_max: ~
lat_min: ~
lon_max: ~
lon_min: ~
ordinal: 5
report_identifier: nca3
source_citation: 'Averyt et al. 20116c050821-4d0f-452a-9fb3-6576a5cc1c2e'
submission_dt: ~
time_end: ~
time_start: ~
title: Water Use for Electricity Generation by Fuel and Cooling Technology
url: http://nca2014.globalchange.gov/report/sectors/energy-water-and-land/graphics/water-use-electricity-generation-fuel-and-cooling
usage_limits: Copyright protected. Obtain permission from the original figure source.
files:
- display_name: 10-5_consumption.png
file: 97/08/f764aa715695395b550f23c223b6/10-5_consumption.png
href: http://data.globalchange.gov/assets/97/08/f764aa715695395b550f23c223b6/10-5_consumption.png
identifier: 720d8c52-8483-4655-b0b1-ebdcbd63478f
landing_page: ~
location: ~
mime_type: image/png
sha1: 3499eaa5bdc7066c0856ae56f5e273ecdb82466a
size: 111829
thumbnail: 97/08/f764aa715695395b550f23c223b6/.thumb-720d8c52-8483-4655-b0b1-ebdcbd63478f.png
thumbnail_href: http://data.globalchange.gov/assets/97/08/f764aa715695395b550f23c223b6/.thumb-720d8c52-8483-4655-b0b1-ebdcbd63478f.png
type: file
uri: /file/720d8c52-8483-4655-b0b1-ebdcbd63478f
url: http://data.globalchange.gov/assets/97/08/f764aa715695395b550f23c223b6/10-5_consumption.png
href: http://52.38.26.42:8080/image/76b0a8ed-2baa-4d9c-88f4-cc87d7bcea77.yaml
identifier: 76b0a8ed-2baa-4d9c-88f4-cc87d7bcea77
lat_max: ~
lat_min: ~
lon_max: ~
lon_min: ~
parents: []
position: ~
references: []
submission_dt: ~
time_end: ~
time_start: ~
title: 'Water Use for Electricity Generation by Fuel and Cooling Technology - Consumption'
type: image
uri: /image/76b0a8ed-2baa-4d9c-88f4-cc87d7bcea77
url: ~
usage_limits: ~